Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

Scientific Reports volume  13, Article number: 2656 (2023 ) Cite this article Cross-Flow Cooling Tower

Design and operation of high-power permanent magnet speed regulator used in industry | Scientific Reports

A high-power permanent magnet speed regulator is applied to a cooling water pump for conserving energy during the steel production in Magang (Group) Holding Co., Ltd. The designed setup of high-power permanent magnet speed regulator with a mobile base is shown in this manuscript, and the magnetic eddy under the different meshing area between driving and driven shafts has been simulated. And estimation indicates that the magnet speed regulator-controlled cooling water pump can save electric energy by 22%, about 1,756,400 kW·h per year, compared to the traditional valve-controlled pump, and the waste heat generated by this setup is below 5 ten-thousandths of the shaft power. Meanwhile, the permanent magnet speed regulator has a much lower vibration because of this non-contact way between the driving and driven shafts.

Compared with the traditional gear box, the permanent magnet speed regulator, which is based on the magnetic eddy due to the relative motion between the permanent magnet and the conductor, has several advantages such as higher energy efficient, stronger reliability, easier installation, lower cost, and soft start of motor1,2. The new technology for permanent magnet adjustable speed is used for the motor to control its speed and save its energy, which is benefit to the emission reduction. Therefore, more and more attention has been paid by the researchers in the industrial field.

Development of the disc-type permanent magnet speed regulator never stops, since it was proposed in 1990s3,4. In recent years, researches on the permanent magnet speed regulator were carried out not only in the items of the model and simulation for the basic analysis5,6, but also in the application with structure improvement in industry7,8. The virtual equivalent line method was developed to solve the end-effect on the magnetic field distribution in the air gap region of permanent magnet speed regulator. Through calculation of the static air gap flux density, it was found that the end-effect compensation function calculated based on the model was highly consistent with the result calculated by finite element method9. According to model for 3D transient eddy field in some research, the substitution of the copper disc by an aluminum disc could improve the speed governing stability of the permanent magnetic coupler10. A fast and accurate 3D modeling method was proposed to evaluate the electromagnetic performance of machines with axial flux permanent magnet under no-load conditions. The computed results of local field density, electromotive force, and cogging torque for the disk speed regulator were in very good agreement with the experimental measurements11. A novel flux-weakening control strategy with fast transient current response is designed to facilitate the flux-weakening control application on electric vehicle, and the simulation and experimental results exhibited that the proposed strategy could achieve the fast torque response and also have the capacity to reduce the torque fluctuation of the stable state12. Structure of 250 kW permanent magnet governor was advanced to improve the heat conduction, guaranteeing the steady as well as reliable operation of this equipment13. Halbach array, a kind of special permanent magnet array, was tried in the permanent magnet coupler, and both the simulation and test showed higher efficiency in the axial speed regulator14,15. In addition, Halbach array was also used in the separators to improve the separation efficiency16. Relatively systematic researches on permanent magnet speed regulator were also shown in the references17,18,19.

In this manuscript, 450 kW permanent magnet speed regulator used for cooling water pump in steel production is shown. N–S pole array structure is used in this speed regulator, and the magnetic field and current density in the conductor driving draft induced by the magnet driven draft are simulated based on finite element modeling (FEM) analysis. Under the motor, an automatic mobile base controlled by programmable logic controller (PLC) is used novelty to adjust the meshing area and consequentially magnetic eddy, changing the output power of the motor to keep the water flow in pipe. Measurement and calculation shows that the magnet speed regulator-controlled cooling water pump in this research can save electric energy by 22%, about 1,756,400 kW·h per year, compared to the traditional valve-controlled pump. Therefore, this kind of permanent magnet speed regulator is in a compact structure (axial pitch is only 25 cm). Furthermore, an obviously reduction of vibration is observed when the permanent magnet speed regulator is used. Meanwhile, waste heat in the setup is very low based on the theory of thermal radiation.

Based on former research and application20,21, the permanent magnet speed regulator, which is used to adjust the high-power cooling water pump during the steel production, is advanced to increase transmission efficiency and heat dissipation efficiency. The structure of the advanced permanent magnet speed regulator with the coordinate system is shown in Fig. 1.

Structure of the permanent magnet speed regulator.

As seen in Fig. 1a, this permanent magnet speed regulator includes motor, driving shaft, and driven shaft dominantly, and the motor is fixed on a mobile base with the track. The driving shaft is fixed on the motor. When the driven shaft is insert into driven shaft along with the track, meshing area between the driving and driven shafts increases as seen in Fig. 1b, enhancing the rotational resistance moment of the motor. In order to keep the rotative velocity, the motor outputs higher power. Detection, judgement, and control to the driving shaft fixed the motor are carried out by PLC.

As seen in Fig. 1b,c, 12 pieces of permanent magnet, which are used as the key component of the driving shaft, are arranged by the alternating N–S pole array on the dodecagon-type base. The copper conductor cylinder is fixed on the inner surface of the sleeve. The dodecagon-type base and the sleeve are made of steel, and also used as yoke iron to strengthen the magnetic intensity in the region between them. Thickness of the air gap hg is defined as the distance from circumscribed circle of the permanent magnet array to the inner surface of the conductor cylinder. The key sizes remarked in figure are shown in Table 1. Magnet designation used in this device is N52.

Insert depth (lt) of the driving unit, which is adjusted by mobile base, can reach to the long size of the permanent magnet in Y axis (lm). The r–θ coordinate system is also introduced into XOZ plane of the Cartesian coordinate system, reducing difficulty of the calculation in simulation. According to Ampere molecular current hypothesis and Biot–Savart law22,23, magnetic intensity induced by the permanent magnet array has been simulated, as shown in Fig. 2.

Simulated magnetic intensity B in the conductor.

As seen in Fig. 2, a relatively higher magnetic intensity was gain due to the yoke iron. The maximal magnetic intensity could be reached to 0.25–0.3 T in the plane away of 9 mm from the magnet array.

According to Maxwell’s equations with Faraday law24,25, induced current density in the copper conductor is as

where σ is the conductivity of copper; B is the vector of induced magnetic intensity; A is an introduced vector named as magnetic potential; v is the vector of relative speed between conductor cylinder and magnet array, and it can be calculated by

where ω is the relative angular frequency between conductor cylinder and magnet array; s, N and r are the slip difference, input rotation velocity, and the vector of polar axis in the r–θ coordinate system.

As seen in formula (3), current density J will be changed in proportional variation with the relative angular frequency ω or slip difference s. Simulated current density of the magnetic eddy induced by the relative motion between the permanent magnet array and the conductor cylinder (ω = 1 rad/s) is shown in Fig. 3, and their vector-graph are shown in Fig. 4c Insert ratio of 100% (Fig. 4).

Simulated current density J in the conductor.

As seen in Figs. 3 and 4, the 12 independent magnetic eddies can be observed clearly under different insert ratios of driving shaft. However, the surficial current intensity of magnetic eddy is influenced seriously by the meshing area due to insert ratio. Higher surficial current intensity of magnetic eddy means the larger magnetic resistance from the driven shaft against the driving shaft16,19. And then the latter will increase the power to keep the set rotative velocity of the motor.

The 450 kW permanent magnet speed regulator used for cooled water pump, as shown in Fig. 5, is tested in Magang (Group) Holding Co., Ltd. Compared with the simulated structure above, a cooling fin array is added in the applied equipment to improve the heat abstraction.

Equipment in the preliminary test.

The basic parameters of motor and load (water pump) are shown in Table 2.

According to the fluid mechanics, the shaft power P is proportional to the product of flow rate Q and torque H, namely

And there are different relations between the parameters and the rotative velocity n, which are given as

Table 3 show the calculated parameters, including the saving rate Rs that is given as

where the Pmax is the shaft power under the maximal rotative velocity.

Figure 6 can show the difference between the running properties of the loads controlled by the traditional valve and the magnet speed regulator in this project. When the flow Q1 decreases to Q2 due to reduced valve in the traditional valve-adjusted mode, the running condition will shift to B from A since the network resistance in pipe increases. The flow is decreased by reducing the valve, however, the rotative velocity is always kept. Therefore, the shaft power cannot be reduced.

On the other hand, the rotative velocity of the motor will be reduced by decreasing the insert depth of the driving unit in the magnet speed regulator. When the rotative velocity of the motor reduce to n2 from n1 and the flow is adjusted to Q2, the pipe also keeps a lower pressure HB. Thus, the shaft power is reduced, and the saving power ΔP is proportional to Q2(H2 − HB) as seen in Fig. 6. According to the statistical data, the magnet speed regulator can save power by 10%–25%. According to rated flow (2020 m3·h−1), rated lift (59 m), and minimal torque (0.45 MPa) of two motors for the cooling water in Magang (Group) Holding Co., Ltd., the rated torque is 0.58 MPa. And the saving rate is (1 − 0.45 ÷ 0.58) × 100% ≈ 22.4%. Then the two motors can save power Ps = 2 × 1.732 × 6000 V × 51.78A × 0.86 × 8472 h ÷ 1000 × 22.4% ≈ 1,756,400 kW·h, and the fee about 833,000 Chinese Yuan (about 120,829 dollars) per year.

Vibration contrast before and after using the speed regulator is also shown in Table 4.

According to the measurement, motor vibration has a remarkable reduction after using the magnetic speed regulator, because there is no solid contact between the driving shaft (conductor) and driven shaft (magnet array), which removes the vibration amplification effect of rigid connection. Meanwhile, there is a relatively higher tolerance against the coaxiality between the driving and driven shafts also because of their non-contact state. On the other hand, a seriously accurate axis alignment whose error is below 0.05 mm is necessary in the traditional valve-controlled pump.

In addition, temperature of cooling fin was 43.4 ℃, as measured in Fig. 7, when the device runs. Waste heat emittance generated by this magnetic speed regulator can be estimated as 134 W/m2, if the cooling fin is supposed as a gray body with an emissivity of 0.85. Area of cooling fin is about 1.3 m2, and the waste heat generated by this magnetic speed regulator can be estimated as 185.9 W which is below 5 ten-thousandths of the shaft power of 450 kW.

Temperature test of the cooling fin.

The designed and applied permanent magnet speed regulator for a cooling water pump can save large electric energy during the process of steel production by adjusting the motor power actively. An alternating N–S pole array is used as the driven shaft and a conductor used as driving shaft in the permanent magnet speed regulator. A mobile base controlled by PLC is used to adjust the meshing area and consequentially magnetic eddy, changing the output power of the motor. According to the calculation, the magnet speed regulator can save electric energy by 22% in cooling water pump, about 1,756,400 kW·h per year, compared to the traditional valve-controlled pump. Furthermore, lower vibration and much lower waste heat are generated in the permanent magnet speed regulator.

The datasets analyzed during the current study available from the corresponding author on reasonable request.

Jing, L. L., Liu, G. C., Guo, X. X. & Su, S. Research on the cloud computing fuzzy proportion integration differentiation control strategy for permanent-magnet homopolar motor with salient pole solid rotor used on new-energy vehicle. Sustain. Energy Technol. Assess. 52, 101969 (2022).

Ducharne, B., Zhang, B. & Sebald, G. Fractional derivative resolution of the anomalous magnetic field diffusion through a ferromagnetic steel rod: Application to eddy current testing. Commun. Nonlinear Sci. Numer. Simulat. 103, 105953 (2021).

Article  MathSciNet  MATH  Google Scholar 

Wallace, A., Wohlgemuth, C., & Lamb, K. A high efficiency, alignment and vibration tolerant, coupler using high energy-product permanent magnets. in Seventh International Conference on Electrical Machines and Drives (1995).

Simon, T. Regulator for Permanent Magnet Generator and Permanent Magnet Generator. British Patent, EP0767530A2, 1997-04-09.

Li, Y. M., Cai, S., Yao, J. F. & Cheng, J. Z. Influence analysis of structure parameters on transfer characteristics of high-power permanent magnet eddy-current coupling. China Mech. Eng. 28(13), 1588–1592 (2017).

Wang, X., Cai, L., Mao, Y. & Guo, W. Analysis of eddy current loss in magnetic coupling based on three-dimensional finite element calculation. J. Phys. Conf. Ser. 2093, 012039 (2021).

Zhang, H., Wang, D. Design optimization of axial-flux Eddy current coupler. in IEEE 3rd Advanced Information Technology, Electronic and Automation Control Conference (2018).

Zhang, R. & Gao, L. Research on the design and optimization of 1.5 MW semi-direct drive permanent magnet synchronous wind turbine. Energy Rep. 8, 589–598 (2022).

Li, W., Wang, D., Kong, D., Wang, S. & Hua, Z. A novel method for modeling the air gap flux density of the axial-flux permanent magnet eddy current coupler considering the end-effect. Energy Rep. 7, 508–514 (2021).

Ming, Wu., Ma, Y., Kuang, J. & Huang, X. Speed governing performance of the permanent magnetic coupler under centrifugal load. J. Mech. Eng. 55(4), 225–232 (2019).

Ouldhamrane, H. et al. Development and experimental validation of a fast and accurate field calculation tool for axial flux permanent magnet machines. J. Magn. Magn. Mater. 552, 169105 (2022).

Wei, H., Jingzhen, Yu., Zhang, Y. & Ai, Q. High-speed control strategy for permanent magnet synchronous machines in electric vehicles drives: Analysis of dynamic torque response and instantaneous current compensation. Energy Rep. 6, 2324–2335 (2020).

Wang, L., Jia, Z. & Zhang, Li. Investigation on the accurate calculation of the temperature field of permanent magnet governor and the optimization method of heat conduction. Case Stud. Therm. Eng. 13, 100360 (2019).

Park, M. G., Choi, J. Y. & Shin, H. J. Torque analysis and measurements of a permanent magnet type Eddy current brake with a Halbach magnet array based on analytical magnetic field calculations. J. Appl. Phys. 115(17), 17E707 (2014).

Jang, G, Kim, J., & Shin, H. Optimal design and torque analysis considering eddy-current reduction of axial-flux permanent magnet couplings with Halbach array based on 3D-FEM. in IEEE Conference on Electromagnetic Field Computation (2016).

Bin, C. et al. Optimization of Halbach magnetic roller for eddy current separation based on the response surface method and multi-objective genetic algorithm. J. Clean. Prod. 278, 123531 (2021).

Wei Cai. Research on Transmission Characteristics of Radial Gap Adjusting Permanent Magnet Eddy Current Coupler. (Haerbin: Harbin Institute of Technology, 2021).

Chunmin, Yu., Deng, Z., Mei, L., Peng, C. & Cao, X. Multiobjective optimization of 3-DOF magnetic bearing considering eddy current effects and saturation. Mech. Syst. Signal Process. 182, 109538 (2023).

The Research About Analytical Modeling and Electromagnetic Characteristic Analysis of Novel Permanent Magnet Adjustable Speed Drives. (Southeast University, 2019).

Sun, Z. S., Zhou, L. P., Wang, X. D. & Huang, Z. N. Magnetic field analysis and characteristics research of cylindrical permanent magnet adjustable speed drive. China Mech. Eng. 26(13), 1742–1747 (2015).

Wang, B., Sun, Z. S., Zhou, L. P. & Wang, X. D. Simulation and experiment on thermal-fluid coupling of air-cooled permanent magnet speed regulator. Mechatronics 23(12), 13–17 (2017).

Gou, X. F., Yang, Y. & Zheng, X. J. Analytic expression of magnetic field distribution of rectangular permanent magnets. Appl. Math. Mech. 25(3), 271–278 (2004).

Wen, H., Liu, S. & Ouyang, J. Calculation and simulation of Eddy current magnetic field of ellipsoid in changing magnetic field. J. Phys. Conf. Ser. 2021, 012108 (1894).

Mirzaei, M., Ripka, P., Chirtsov, A. & Grim, V. Eddy current speed sensor with magnetic shielding. J. Magn. Magn. Mater. 502, 166568 (2020).

Jinnan, Lu., Liu, Z., Zeng, W. & Ren, Ze. New PWM predictive control suitable for low carrier ratio of permanent magnet synchronous motor drive systems. J. Power Electron. 21, 881–891 (2021).

This paper is supported by Industrial Collaborative Innovation Special Fund Project of Anhui Polytechnic University & Jiujiang District (2022cyxtb8), Start-up Fund for the Introductions of AHPU (2022YQQ001), and National Natural Science Foundation of China (12205004).

School of Mechanical Engineering, Anhui Polytechnic University, Wuhu, China

Yimin Lu, Chunlai Yang, Long Shao & ManMan Xu

Wuhu Magnetic Wheel Transmission Technology Ltd., Wuhu, China

Xiangdong Wang, Hui Zhu & Aike Wang

You can also search for this author in PubMed  Google Scholar

You can also search for this author in PubMed  Google Scholar

You can also search for this author in PubMed  Google Scholar

You can also search for this author in PubMed  Google Scholar

You can also search for this author in PubMed  Google Scholar

You can also search for this author in PubMed  Google Scholar

You can also search for this author in PubMed  Google Scholar

Y.L. and C.Y. performed the data analyses, and writing the main manuscript text. X.W. contributed to the conception of the study. H.Z. and A.W. offered the main onsite testing technology, and prepared Figs. 1, 5 and 6. L.S. and M.X. carried out the simulation, and prepared Figs. 2, 3 and 4. All authors reviewed the manuscript.

The authors declare no competing interests.

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Lu, Y., Wang, X., Yang, C. et al. Design and operation of high-power permanent magnet speed regulator used in industry. Sci Rep 13, 2656 (2023). https://doi.org/10.1038/s41598-023-29187-7

DOI: https://doi.org/10.1038/s41598-023-29187-7

Anyone you share the following link with will be able to read this content:

Sorry, a shareable link is not currently available for this article.

Provided by the Springer Nature SharedIt content-sharing initiative

By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.

Scientific Reports (Sci Rep) ISSN 2045-2322 (online)

Design and operation of high-power permanent magnet speed regulator used in industry | Scientific Reports

Cooling Tower Water Treatment Chemicals Sign up for the Nature Briefing newsletter — what matters in science, free to your inbox daily.